概述Akreos® AO60 与 MI60L 为非球面亲水性丙烯酸人工晶状体,设计用于微切口白内障手术,提供多种度数与结构以支持精准的中心定位和稳定性。
主要特性- 光学设计在已发表文献中显示可提供良好的视力和对比敏感度
- 高柔韧性,允许通过最小 1.8 mm 切口植入
- 三种总体长度与四点支撑结构,确保可预测的配合、中心定位和旋转稳定性
- 等双凸光学设计与低折射率材料以减小反射光
技术参数Model | Recommended Starting A-Constant | Overall Diameter | Diopter Powers
AO60 | 118.5* | 11.0 mm (+0 to +15 D); 10.7 mm (+15.5 to +22 D); 10.5 mm (+22.5 to +30 D) | +0 D to +9 D in 1.0 D steps; +10 D to +30 D in 0.5 D steps
MI60L | 119.1* | 11.0 mm (+0 to +15 D); 10.7 mm (+15.5 to +22 D); 10.5 mm (+22.5 to +30 D) | +0 D to +9 D in 1.0 D steps; +10 D to +30 D in 0.5 D steps
*A 常数为光学生物测量的估算值。建议每位外科医生建立自身的参考值。
光学体直径 / 给药系统光学体直径(AO60 型号) | 6.2 mm (+0 to +9 D); 6.0 mm (+10 to +30 D)
光学体直径(MI60L 型号) | 6.2 mm (+0 to +15 D); 6.0 mm (+15.5 to +22 D); 5.6 mm (+22.5 to +30 D)
给药系统 | VIS100; AI-28; INJ100(因型号而异)
规格- 系列 / 名称:Akreos®
- 可选型号:AO60, MI60L
- 推荐起始 A 常数:AO60 = 118.5*;MI60L = 119.1*(*光学生物测量估算)
- 总体直径按度数:低度数 11.0 mm,中度数 10.7 mm,高度数 10.5 mm,视型号而定
- 度数范围与递增:+0 D 至 +9 D,步距 1.0 D;+10 D 至 +30 D,步距 0.5 D
- 切口大小:最小 1.8 mm
- 光学形状:非球面
- 材料(光学体与支架):亲水性丙烯酸,含紫外线阻隔剂
- 35°C 折射率:1.458
- 光学体直径(AO60):6.2 mm (+0 至 +9 D);6.0 mm (+10 至 +30 D)
- 光学体直径(MI60L):6.2 mm (+0 至 +15 D);6.0 mm (+15.5 至 +22 D);5.6 mm (+22.5 至 +30 D)
- 参考给药系统:VIS100、AI-28、INJ100(视型号而定)
- 设计说明:为微切口植入优化的柔韧性;三种长度以适配;四点支撑以提升中心定位和稳定性;等双凸光学与低折射率材料以减少反射
参考文献 / 说明1. Jorge L. Alió, MD, PhD, David P. Piñero , MSc, Dolores Ortiz, PhD, Raúl Montalbán, OD. Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens. J Cataract Refract Surg 2009; 35:1548-1554.
2. Akreos MICS DFU.
3. Izzet Can, Tamer Takmaz, Yelda Yildiz, Hasan Ali Bayhan, Gulizar Soyugelen, Basak Bostanci. Coaxial, microcoaxial, and biazial microincision cataract surgery. J Cataract Refract Surg 2010; 36:740-746.
4. Marcony R. Santhiago, Marcelo V. Netto, Jackson Barreto Jr, Beatriz A. F. Gomes, Adriana Mukai, Ana Paula Calil Guermandi, Newton Kara-Junior. Wavefront Analysis, Contrast Sensitivity, and Depth of Focus After Cataract Surgery With Aspherical Intraocular Lens Implantation. American Journal of Ophthalmology, March 2010, Vol. 149, No. 3.
5. Phillip J. Buckhurst, James S. Wolffsohn, Shehzad A. Naroo, Leon N. Davies. Rotational and centration stability of an aspheric intraocular lens with a simulated toric design. J Cataract Refract Surg 2010; 36:1523-1528.
6. Data on file: Recommended incision size memo.
7. Eric JC et al. Analysis of postoperative glare and intraocular lens design. J Cataract Refract Surg. 2001; 27:614-21.